The following article will guide you through using the C99-T02 reduced encumbrance catenary cantilevers in Lineardraft, by providing you with:
- An annotated example with all limits for user adjustable values
- The system height and reach ranges for using the cantilevers in your design
C99-T02 Reduced Pull Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77138564963/original/t_doPtKx-bWVmJlH4XsjjnvZgGr5loR4rQ.jpg?1695203294)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 600mm
- Maximum System Height: 1500mm
- Minimum Reach: 1857mm
- Maximum Reach: 3710mm
C99-T02 Reduced Braced Pull Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77138565034/original/Dg0yKH6dy6XgeVnpuiZEZtZ4dHdr7NzWfA.jpg?1695203307)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 600mm
- Maximum System Height: 1500mm
- Minimum Reach: 1857mm
- Maximum Reach: 5060mm