Default Schematic Backtie Symbology

Defines the length of the backtie symbol line when the selected 'Backtie position' option is 'Schematic' as shown below.

This means, regardless of the real-world position of the backtie, the backtie symbology will remain perpendicular to the structure symbol, with the line length defined by this setting.

Options:

A number, expressed in metres.

Default Setting: 5m

Changing properties: If you want to change the option of this property, your Project Settings Administrator must request a project settings change.